Menu Close

Do you need to fire block interior walls?

Do you need to fire block interior walls?

Although interior walls must be fireblocked, there is no 4′ requirement in the IRC code. They must be fireblocked at the platelines and any spaces that exceed 10′ heights. 4′ blocks are typically for blocking edges of exterior sheathing laid horizontally, and aren’t intended to serve as fireblocks.

Which walls require fire blocking?

These requirements, contained in IBC 2015 Section 718.2. 2, state that fire blocking is required vertically at the ceiling and floor levels and horizontally at intervals not exceeding 10 feet. Additionally, IBC Section 718.2.

When should fire blocking be installed?

Fire blocking is needed when wood and steel stud walls only have drywall on one side because the fire is now able to go around the top plate and up into the framing above. Sometimes it is hard to see where you need fire blocking.

What is Fireblocking and where would it be in a house?

The purpose of fire blocking is to prevent fire from spreading through the concealed spaces of a building. In an unblocked balloon-framed building, for example, a fire that starts in the basement can rapidly travel up the stud bays and spread into the joist bays and attic.

Do 10 foot walls need blocking?

Blocks for safety But many of today’s codes do require fire blocks in walls that are more than 10 ft. high, like rake walls. When they are needed, cut the blocks to length and nail them between the studs while framing the wall on the floor. If a fire did get started in one of these places, blocks would help contain it.

Do all walls have Fireblock?

Most blocking mid-wall are not fireblocks. Some contractors think they have to do it. Other contractors do it as a method of keeping the wall studs straight. In an outside wall it could be part of a shearwall assembly, which requires the joints between the exterior plywood sheathing to be blocked.

Is blocking necessary in framing?

So any sheathing edges that don’t land on standard framing (studs, plates, windows/doors) need to be supported by blocking. All edges of wall sheathing must be supported by and nailed to framing. This edge didn’t land on plates, so install blocking to support it.

Can I use OSB for fire blocking?

to fire block at these locations will no longer be accepted. OSB with any joints overlapped at least 3″ with an additional layer of 3/4” OSB or 26 ga sheet metal w/ joints overlapped. Fire Blocking must block the concealed space and between the studs.

Where is fire blocking required in a building?

Ask your building inspector) Fire blocking is required inside concealed spaces both horizontally and vertically just like basement walls.

What do you need to know about fireblocks?

Fireblocking involves the use of field-installed building materials to prevent the movement of undetected flames and gases to other areas through such concealed spaces. Although such materials are not required to be tested for fire resistance, they are to be installed to slow fire migration, and to contain a fire until it can be suppressed.

When do you need to fireblock a lane?

Fireblocking is required only at the juncture of each alternate lane and at the ends of each 5 / 8 inches (41 mm) where the concealed space is not required to be fireblocked by Section 718 space shall not be required to meet the ASTM E136 requirements. For the fireblocking of chimneys and fireplaces, see Section R1003.19. Fireblocking …

Where is the best place to put fire blocks?

There are several ways to fire block an area like this. Typically, fire blocks are installed in the stud bays next to soffits. If drywall has been installed on the wall before the soffit is built, no additional fire blocking is needed.